FlexWave™ Universal Radio Head
Flexible Outdoor Coverage and Capacity
Remote Unit
Host Unit
FlexWave™ – ADC’s Next Generation of Wireless Solutions
for Improving Wireless Capacity, Coverage, Flexibility
and Customer Retention
ADC’s FlexWave™ Universal Radio Head (URH) is the most flexible, scalable and
complete solution for addressing coverage and capacity needs for current and
emerging wireless networks. The URH improves wireless network coverage and
capacity by extending services from existing cell sites, to hard-to-reach areas by
distributing coverage from a centralized radio suite.
Utilizing a centralized distributed architecture, service providers are able to recognize
significant CAPEX savings through a shared Base Station Hotel (multiple BTS co-located
together), as well as a shared Remote Radio Transceiver approach. The URH’s flexibility
and scalability offers service providers an optimal solution for multiple applications
such as; dense urban centers, dense suburban areas, campuses, enterprise buildings,
subways and tunnels. The URH’s distributed architecture and small form factor allows
service providers to cost-effectively increase coverage and capacity in these hard-to-
reach areas.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
FlexWave™ Universal Radio Head
Flexible Outdoor Coverage and Capacity
System Description
Future Enhancements
Will Include:
The URH is a flexible and cost effective solution
for Distributed Antenna System applications:
Microcell and/or CPRI/OBSAI Remote Radio Head
applications:
• CPRI/OBSAI; flexibility to support BTS
interface standards
• Microcell; fully contained capacity
solution utilizing cost efficient low
bit-rate IP backhaul
• Next Generation DAS; optimized for
multiple frequency bands, scalable
RF bandwidth & transport rates
• IP ready platform; smooth integration
• Flexible SeRF technology; serial RF
processing, enabling scalable frequency
bands and bandwidths
to IP front/backhaul networks
• Digitial RF Transport; Digitally transports
RF from the BTS to remote locations for
distribution of RF signals.
OBSAI (Future)
Multiplexed
SeRF over
mm-wave
SeRF
Digital
Base
Station
OBSAI to
SeRF Converter
RF
SeRF
800 MHz
Base
RF to SeRF
Converter
SeRF
Board
Multiband,
Station
protocol-agnostic
Universal Radio
Head
RF
SeRF
Multiplexed
SeRF over
Fiber
1900 MHz
Base
Station
RF to SeRF
Converter
Data
Backhaul
Multiplexed
SeRF over
mm-wave
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
3
FlexWave™ Universal Radio Head
Flexible Outdoor Coverage and Capacity
Host Unit
Host Unit
The rack-mountable URH Host Unit is typically
located at a Base Station or a facility housing
a suite of Base Stations. On the forward path,
the Host Unit receives the RF signal from the
BTS and digitizes the designated RF band and
digitally transports it over single mode fiber or a
Millimeter Wave link to the Remote Unit. On the
reverse path, the Host Unit receives the digitized
RF signal from the remote unit and converts it
back to RF for the BTS.
In addition to sending alarm notifications to
the Element Management System (EMS) through
software, the URH Host Unit also features front
panel alarm reporting. LEDs on the front panel
of the Host Unit will change color depending
on the status of the unit. LED displays provide
information regarding the following items:
• Power
• System mode (active/standby)
• Indicate faulty unit
• RF conditions
The URH Host Unit is completely modular in
design, with all major modules; SeRF (Serial RF)
card, DART (Digital/Analog Radio Transceiver)
card, Power Supply, System board and Fan
being hot swappable.
The URH Host Unit supports up to eight DART
cards (supporting up to eight remote units) and
is capable of simulcasting signals up to as many
as eight Remote Units.
The Host Unit utilizes an embedded element
management system for system configuration
and network monitoring. The embedded EMS
collects alarm information from both the Host
and Remote Units. For multiple link deployments,
multiple Host Units can be networked together
at the same BTS site. Host Units can be daisy-
chained together to allow monitoring and
control of multiple Remote Units from a
single user interface.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
4
FlexWave™ Universal Radio Head
Flexible Outdoor Coverage and Capacity
URH Remote Unit
Remote Unit
The URH Remote Unit utilizes a modular design,
which supports up to three bands. Each side
panel/door represents a single-band allowing
for future upgrades and easy field access.
On the forward path, the Remote Unit
receives the digitized spectrum from the Host
Unit and converts the spectrum back into RF to
be distributed via an externally mounted antenna
system. On the reverse path, the Remote Unit
digitizes the designated RF spectrum and digitally
transports it over single-mode fiber or MMW
to the Host Unit.
Mounting options for the Remote Unit include:
pole-mount, inside pole-mount, wall-mount,
strand-mount (singe-band unit only), and
sub-terrain vault-mount.
In addition to sending alarm notifications to
the EMS software, the URH Remote Unit also
features LED alarm reporting. An LED on the
bottom of the Remote Unit will illuminate
upon a fault condition.
The URH Remote Unit is a fully sealed IP-65 rated
enclosure, which minimizes maintenance and is
ideal for harsh environments. Fiber, antenna, and
power input/output connectors are all sealed for
maximum protection.
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
5
FlexWave™ Universal Radio Head
Flexible Outdoor Coverage and Capacity
Alarm and Management System
Network Monitoring Capabilities
The URH utilizes an embedded network
The embedded EMS allows for remote alarm
monitoring and network control of the
URH can also be performed from an off-site
location or Network Operation Center (NOC).
Communications to the NOC can be performed
using the web based interface or SNMP protocol.
management for system configuration and
network monitoring. The element management
system (EMS) utilizes a web based interface or
SNMP protocol for easy accesses to the system.
The Element Management System (EMS) provides
operational and maintenance capabilities for the
URH system (Host and Remote). The EMS can be
used to access and monitor status of any Host
and any associated Remote Units. The EMS has
the ability to view status and parameter settings,
download software, change parameters and
monitor system performance and alarms
The EMS performs the following functions at
off-site locations such as the NOC:
• Provides real-time information regarding faults
• Displays various system level values
(voltages, RF, power, etc.)
• Adjusts performance-related parameters
of the Host Unit and Remote Unit
Access and troubleshooting can also be
accomplished on-site at either the Host Unit
and/or the Remote Unit by utilizing a craft
interface. Thus, allowing technicians the ability
to plug-in a laptop and access all associated
units connected to it.
• Permits placement of Host Unit and Remote
Unit into standby mode
• Access records and generates history reports
with time and date stamps
• Allows download of new software versions
to the Host Unit and Remote Units
Host Site Capabilities
The EMS performs the following functions
at the Host site:
• Provides real-time information regarding faults
• Set up simulcast ratios
• Digital timing delays
• Displays various system level values
(voltages, RF, power, etc.)
• Records and generates history reports with
time and date stamps
• Adjusts performance related parameters
of the Host Unit and Remote Unit
• Permits placement of Host Unit and Remote
Unit into standby mode
• Allows download of new software versions
to the Host Unit and Remote Units
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
6
FlexWave™ Universal Radio Head
Flexible Outdoor Coverage and Capacity
Specifications
RF SpeciFication
Supported Frequency Blocks:
Bandwidth:
1-3 per Remote Unit; 1-8 per Host Unit
1.5 to 35 MHz non-contiguous
Frequency Band Supported:
800 Cellular, E-SMR 800/900,
1900 PCS 1700/2100 AWS
700, 1800 and 2500MHz (Future Releases)
Up to 8:1 Single Host (can daisy chain Host for higher simulcast)
Yes (Optional)
Digital Simulcast:
Diversity Receive:
pRopagation Delay
System Delay:
<12 microseconds
Delay Management:
Digital (Manual or Automatic)
noiSe FigURe
noise Figure:
input ip3:
<5 dB
>-8 dBm
optical SpeciFicationS
optical Budget:
10 dB (Standard); 26 dB (Optional)
3.072 Gbps
Digital transport Rate:
oUtpUt poweR
output power per Band:
38 dBm (6.5 Watts) Cell/SMR
43 dBm (20 Watts) PCS
43 dBm (20 Watts) AWS
ReMote Unit enViRonMental SpeciFicationS
outside ambient
temp Rating:
-40°C to +50°C
Storage temperature:
Humidity:
lightning protection:
-40°C to +70°C
10% to 90% non-condensing
20kA IEC 1000-45 8/30 µs Waveform
ReMote Unit
enclosure:
IP-65
Mounting:
Dimensions (H x w x D):
Volume:
Wall, Pole, Inside Pole, Strand, and Vault
29.38" x 16.45" x 15.6"
3.66 Cubic Feet
weight:
cooling:
≤200 Pounds (No one component >80 lbs.)
Passive Convection
optical connectors:
Sealed Proax
HoSt Unit
Mounting:
Dimensions (H x w x D):
weight:
19- and 23-inch rack
5.25" x 19" x 19" (3 RUs)
<25 Pounds
ReMote Unit poweR ReqUiReMentS
power Supply:
100-240 VAC, 50-60 Hz
Yes (External)
Battery Backup:
power consumption:
~1000 Watts (Fully loaded 20 W doors)
HoSt Unit poweR ReqUiReMentS
power Source:
24 to 48 VDC
power consumption:
~250 Watts (Fully loaded with 8 DARTs)
element Management
embedded eMS:
Yes
Yes
SnMp Based Management:
Note: Unless noted otherwise specifications are typical and subject to change
w w w . a d c . c o m
•
+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0
•
1 - 8 0 0 - 3 6 6 - 3 8 9 1
7
URH Host Unit Configuration Examples
O rd e r i n g I n f o r m a t i o n
Description
catalog number
FWU-20000000HU
FWU-45000000HU
FWU-80000000HU
FWU-A0000000HU
FWU-28000000HU
FWU-28A00000HU
FWU-458W0000HU
FWU-45800000HU
Host unit, one DART, 800 cell
Host unit, one 800 SMR and one 900 SMR DART
Host unit, one DART, 1900 PCS
Host unit, one DART, 2100 AWS
Host unit, one 800 cell, one 1900 PCS DART
Host unit, one 800 cell, one 1900 PCS, one AWS DART
Host unit, one 800 SMR, one 900 SMR, one 1900 PCS, one 2.5 WiMAX DART
Host unit, one 800 SMR, one 900 SMR, one 1900 PCS DART
URH Remote Unit Configuration Examples
O rd e r i n g I n f o r m a t i o n
Description
catalog number
800 cell A, 6.5W, single band, N/D, putty white, remote unit
1900 PCS, 20W, single band, diversity, putty white, remote unit
800/900 ESMR 6.5W N/D, 1900 PCS 20W N/D, putty white, remote unit
Three 1900 PCS, 20W, N/D, putty white, remote unit
2100 AWS, 20W, single band, N/D, putty white, remote unit
FWU-2210000000111RU
FWU-8420000000111RU
FWU-D218410000111RU
FWU-8418418410111RU
FWU-A410000000111RU
FWU-D21841W5M0111RU
800/900 ESMR 6.5W N/D, 1900 PCS 20W N/D, 2.5 WiMAX 10W MIMO, putty
white, remote unit
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC’s global sales office locations, please refer to our website.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
105502ae 4/08 Revision
©
2008 aDc telecommunications, inc. all Rights Reserved
|