Installation
Instructions
COPELAND
Centerset Lavatory Faucet
with Speed Connect™ Drain
7005.201
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
Speed Connect Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the !rst time, every time.
Certified to comply with ANSI A112.18.1
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
M968635 REV.1.1
Recommended tools
Tubing Cutter
Screwdriver
Channel Locks
Adjustable Wrench
Turn off hot and cold water
supplies before beginning.
INSTALL FAUCET
CAUTION
1
Insert FAUCET (1) and CABLE CONNECTOR (2) through
mounting holes of Sink or Mounting Surface. Fig. A.
Fig. A.
Assemble LOCKNUTS (3) onto SHANKS (4) from under
side of Sink. Hand tighten firmly. Fig. B.
(HAND TIGHTEN)
1
4
3
POP-UP
CABLE
4
Fig. B.
SINK OR
MOUNTING
SURFACE
3
2
2
1
ATTACH CABLE CONNECTOR
7
8
Fig. A.
Fig. B.
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
1
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
2
1-1/4” O.D.
CHECK OPERATION OF POP-UP
1
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then refer
to the “troubleshooting section” of these instructions.
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS
9
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
1/2" PIPE
THREAD
1
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
COUPLING
NUT
2
FLEXIBLE
SUPPLIES
3
3/8 O.D.
BULL-NOSE
RISERS
3/8” COMPRESSION
CONNECTION
COMPRESSION
NUT
FERRULE
HOT
COLD
M968635 REV.1.1
3
TEST INSTALLED FITTING
10
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
Remove AERATOR (3).
4
Operate both HANDLES (1) to flush water lines thoroughly.
1
Replace AERATOR (3).
1
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.
Check that DRAIN STOPPER (5) makes a good seal
and retains water in SINK. If DRAIN STOPPER (5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
3
Release POP-UP KNOB (4) down and check all drain
connections and "P" trap for leaks.
if necessary.
Tighten
5
WASTE
OUTLET
2
2
“P” TRAP
SERVICE
11
To change direction of handle:
Turn valve to OFF position
Remove SET SCREW (6) with 5/64" Hex Wrench.
Pull HANDLE (1) “UP” firmly to release from ADAPTER (2).
Pull HANDLE BASE (7) off of CARTRIDGE (8).
1
6
Remove ADAPTER SCREW (3) from ADAPTOR (2).
Pull off ADAPTER (2).
7
3
90˚
Remove SPRING CLIP (4). Lift STOP WASHER (5),
turn 90˚ and replace. Replace SPRING CLIP (4).
5
2
8
4
Replace ADAPTER (2) and ADAPTER SCREW (3).
Find correct position of HANDLE ASSEMBLY (1)
by adjusting male teeth on ADAPTER (2) to female
teeth in HANDLE ASSEMBLY (1).
Push HANDLE (1) down onto ADAPTER (4) until it
snaps into place.
CARE INSTRUCTIONS:
12
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968635 REV.1.1
4
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
DOWN
Fig. A.
Fig. B. Fig. C.
CAM
1
LIFT-KNOB
RE-ATTACH
STOPPER
CAM CAP
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. D.
Fig. E.
Fig. F.
REMOVE
CAM
REMOVE
CAM CAP
M968635 REV.1.1
5
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
Fig. G.
LOGO
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Locked Mode
(Vandal Proof)
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
Fig. H.
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
LOGO
180˚
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
FRONT OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Unlocked Mode
Fig. J.
Fig. K.
CAM
INSTALL CAM
INSTALL
CAM CAP
M968635 REV.1.1
6
|