AMARILIS™
TM
Personal Shower System
Installation Instructions for:
DELUXE SHOWERHEAD
BODY SIDE SPRAY
1660.100 SERIES
1660.120 SERIES
ROUGHING-IN DIMENSIONS
FINISHED
WALL
DELUXE SHOWERHEAD
1-1/2"
OPTIONAL TO
1/2"
MAX.
FINISHED FLOOR
USUALLY 65" TO 78".
FOR USE WITH BODY
SIDE SPRAYS 72" TO 78"
IS RECOMMENDED.
6-1/2"
BODY SIDE SPRAY
FINISHED
WALL
RECOMMENDED INSTALLATION FOR
MULTIPLE BODY SIDE SPRAYS:
1-1/2"
Each installed BODY SIDE SPRAY requires
2.5 GPM for an adequate spray flow.
For maximum flow, use Amarilis 3-Handle
Bath/Shower Valve 8030 or 8031 Series.
1/2"
MAX.
SEE
RECOMMENDED
INSTALLATION
BELOW
4-3/4"
Connect multiple body side sprays to spout
outlet of valve.
Provide two-way diverter valve for addition of
tub spout.
TO SHOWERHEAD
1/2" S.P.S.
16"
16"
Connect deluxe showerhead to shower outlet
of valve.
3 HANDLE
B/S VALVE
24"
4"
32" OPTIONAL
TO FINISHED
FLOOR
28" OPTIONAL
TO FINISHED
FLOOR
TWO-WAY
DIVERTER
VALVE
TUB SPOUT
- 2 SPRAY
- 3 SPRAY
1
2
ROUGHING-IN
Prepare shower connection nipples per roughing-in
dimensions. See diagram for recommended 2 and 3
BODY SIDE SPRAY installation.
Cap nipples, turn on water supplies and check for leaks.
SHOWERHEAD INSTALLATION
Slide ESCUTCHEON forward and compress
BELLOWS to expose supply connectors.
Turn on water supplies and check for leaks.
Push ESCUTCHEON back until seated flush against
wall.
Use adjustable wrench to install SHOWERHEAD.
3
SERVICE
COUPLING
NUT
SUPPLY
CONNECTOR
To increase swivel tension:
Compress BELLOWS towards rear to expose ball joint.
Wrench tighten COUPLING NUT to increase tension.
The FLOW REGULATOR may accumulate debris causing
reduced water flow. To clean, remove SHOWERHEAD,
then:
Remove ESCUTCHEON and BELLOWS.
Unscrew SUPPLY CONNECTOR to remove FLOW
REGULATOR.
Clean FLOW REGULATOR, re-assemble and install
SHOWERHEAD.
FLOW
REGULATOR
ESCUTCHEON
AND
BELLOWS
All product names listed herein are trademarks of American Standard Inc.
Printed in West Germany
C
American Standard Inc. 1990
30449
|