American Standard Plumbing Product 7430801 User Manual

Installation  
Instructions  
BERWICK/ BOULEVARD™  
SPREAD LAVATORY FAUCET  
with Speed Connect™ Drain  
7430.801  
7430.821  
7431.801  
7431.821  
7430.821  
7431.821  
Congratulations on purchasing your American Standard  
faucet with Speed Connect drain, a feature found only on  
American Standard faucets.  
7430.801  
7431.801  
Certified to comply with ANSI A112.18.1  
Speed Connect Drain*  
M968640 REV.1.1  
• Fewer parts, installs in less time  
• Never needs adjustment  
• Guaranteed to seal properly the first time, every time.  
*Your new American Standard faucet is designed to work only with the Speed Connect drain.  
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.  
Recommended tools  
Tubing Cutter  
Screwdriver  
Channel Locks  
Adjustable Wrench  
Turn off hot and cold water  
supplies before beginning.  
CAUTION  
INSTALL FAUCET  
1
NOTE: READ STEP #16 BEFORE INSTALLING SPOUT TO CONVERT FROM SWIVEL TO FIXED SPOUT.  
Seat SEAL (1) into under side of SPOUT BASE (2).  
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN  
CABLE ASSEMBLY (8) through the mounting hole of lavatory or  
mounting surface. Figure A.  
From below, slide DRAIN CABLE ASSEMBLY (8) and FAUCET SUPPLIES (3)  
through opening in the SPACER (9) against underside of deck. Figure B.  
Note: For thick deck installaitons the SPACER (9) is not required.  
From below, push GASKET (7) and RETAINING WASHER (5) onto  
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),  
pulling faucet to front of sink, so SUPPLIES (3) rests against  
mounting hole. Before final tightening, make sure collar on  
MOUNTING NUT (6) is seated into RETAINING WASHER (5).  
Figure B.  
Figure A  
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)  
to complete faucet mounting.  
GROOVE  
2
1
(FAUCET  
BASE)  
4
9
MOUNTING  
SURFACE  
3
5
7
5
Figure B  
6
4
COLLAR ON  
MOUNTING NUT  
8
1
 
POP-UP DRAIN  
5
6
Fig. A.  
Fig. B.  
Remove CLEAR PLASTIC COVER (1).  
1
3
Remove CARDBOARD SPACER (2) from under  
DRAIN POP-UP (3).  
DRAIN  
BODY  
Tighten TAILPIECE (4) on DRAIN BODY before  
installing DRAIN BODY. Fig. B.  
2
4
REMOVE FLANGE  
Fig. A.  
Fig. B.  
1
Thread FLANGE (1) counter-clockwise and remove  
FLANGE (1) and FOAM GASKET (2) from drain  
body. Fig. A.  
Thread LOCKNUT (3) clock-wise to bottom of  
drain body. Push GASKET (4) down against  
LOCKNUT (3). Fig. B.  
4
3
2
INSTALL DRAIN FROM  
BELOW FIXTURE  
TIGHTEN LOCKNUT  
7
9
8
REAR OF SINK  
Tighten LOCKNUT (1) firmly with Adjustable  
Wrench or Channel Locks.  
From under side of SINK  
install DRAIN BODY (1) up  
4
through drain outlet.  
DRAIN  
OUTLET  
Note: No plumber’s putty  
or caulk is required.  
3
The CABLE ATTACHMENT  
POINT (2) must face towards  
the rear of the SINK.  
1
1
2
Install FOAM GASKET (3) and  
FLANGE (4) onto drain body  
from above SINK and tighten  
FLANGE (4) firmly.  
FLANGE GASKET AND POP-UP KNOB  
Fig. A.  
DOWN  
Check DRAIN FLANGE in SINK to ensure that  
WHITE FOAM GASKET (3) is fully compressed  
and not visible. Fig. A.  
WHITE FOAM  
GASKET  
NOT VISIBLE  
POP-UP KNOB (1) must be fully down. Fig. B.  
DRAIN  
FLANGE  
1
M968640 REV.1.1  
3
 
ATTACH CABLE CONNECTOR  
10  
Fig. A.  
Fig. B.  
Thread CABLE CONNECTOR (1) clockwise  
onto DRAIN BODY CONNECTION (2) and  
hand tighten. Fig. A.  
1
Your new POP-UP DRAIN installation is  
now complete. Fig. B.  
Note: Tailpeice on pop-up drain is 1-1/4” O.D.  
Fig. B.  
2
1-1/4” O.D.  
CHECK OPERATION OF POP-UP  
11  
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and  
closes.  
Note: If STOPPER (2) does not open and close properly then refer  
to the “troubleshooting section” of these instructions.  
1
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS  
12  
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE  
PURCHASED SEPARATELY.  
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE  
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use  
adjustable wrench to tighten connections.  
COUPLING  
NUT  
Do not over tighten. Be careful not to kink copper supply when  
bending. Use tubing cutter to cut to proper length.  
1
2
3
FERRULE  
M968640 REV.1.1  
4
 
TEST INSTALLED FITTING  
13  
With HANDLES (1) in OFF position, turn on WATER  
SUPPLIES (2) and check all connections for leaks.  
6
1
Remove AERATOR (3). First loosen aerator set screw with  
HEX WRENCH (6) supplied. Pull out AERATOR (3) with  
AERATOR KEY (7).  
AERATOR  
SET  
SCREW  
Operate both HANDLES (1) to flush water  
1
3
7
lines thoroughly.  
Replace AERATOR (3) and tighten set screw.  
5
CHECK DRAIN CONNECTIONS  
14  
Operate POP-UP KNOB (5) and fill Sink with water. Check  
that DRAIN STOPPER (4) makes a good seal and retains  
water in Sink. If STOPPER (4) does not seal properly, please  
refer to “Troubleshooting Guide” in these instructions.  
4
Release POP-UP KNOB (5) down and check all drain  
connections and "P" trap for leaks.  
if necessary.  
Tighten  
WASTE  
OUTLET  
2
COLD  
“P” TRAP  
2
HOT  
SPOUT CAN BE FIXED OR SWIVEL.  
CONVERT TO A FIXED SPOUT IF DESIRED.  
SERVICE  
15  
16  
To change from swivel to fixed spout, proceed as follows:  
Remove PLUG BUTTON (1) from back of spout. VIEW “A”  
Remove SET SCREW (2) using screwdriver.  
Install FIXING SET SCREW (3) using Hex Wrench supplied.  
Align SPOUT (4) and tighten SET SCREW (3) to secure SPOUT (4).  
Replace PLUG BUTTON (1).  
To change direction of handle  
rotation, proceed as follows:  
Turn valve to OFF position.  
Thread counter-clock wise  
HANDLE BASE (1) to remove  
HANDLE ASSEMBLY (2) from  
ESCUTCHEON BASE (3).  
Use a flat blade screw driver  
to remove SPRING CLIP (4).  
Lift STOP WASHER (5), turn 90˚  
and replace.  
Replace SPRING CLIP (4).  
Reinstall HANDLE ASSEMBLY (2).  
2
1
1
3
VIEW "A"  
4
If spout drips, operate handles  
several times from OFF to ON  
position. Do not force - handles  
turn only 90˚.  
2
90˚  
5
3
VIEW "A"  
4
1
VALVE  
CARE INSTRUCTIONS:  
17  
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.  
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A  
CLOTH WITH A COARSE SURFACE.  
M968640 REV.1.1  
 
5
Speed Connect™ Drain  
Troubleshooting Guide  
If sink does not hold water even though Stopper is in the “down” position:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If Stopper does not raise up fully or sink drains too slowly:  
• Follow CABLE ADJUSTMENT PROCEDURE.  
If you need to remove the Stopper:  
• Follow STOPPER REMOVAL PROCEDURE.  
If you would like the ability to remove your Stopper simply by lifting it out of the drain:  
Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.  
CABLE ADJUSTMENT PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as  
“Cam” in the illustration. Fig. B.  
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the  
Stopper should be in the UP position. Fig. B, C.  
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.  
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the  
Drain Body Connection (2) and hand-tighten. Fig. A.  
Fig. A.  
Fig. B. Fig. C.  
DOWN  
CAM  
1
RE-ATTACH  
CAM CAP  
1
STOPPER  
DISCONNECT  
2
STOPPER REMOVAL PROCEDURE  
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.  
Look at the area on the Drain Body where the Cable was attached and locate the component labeled  
as “Cam” and “Cam Cap” in the illustration. Fig. B.  
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.  
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.  
The Stopper can now be removed by lifting it out of the Drain. Fig. F.  
Fig. F.  
Fig. D.  
Fig. E.  
REMOVE  
CAM  
REMOVE  
CAM CAP  
M968640 REV.1.1  
 
6
STOPPER INSTALLATION PROCEDURE  
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be  
removed) or “Unlock” Mode (Stopper is removable).  
Locked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. G.  
Fig. G.  
LOGO  
To install the stopper in “Locked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the rear of the  
Sink and the American Standard logo is facing front. Rotate  
Stopper slightly if necessary so that the Stopper slides all the  
way down.Fig. G.  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
REAR OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
DRAIN  
the Cam to make sure it is fully inserted. Fig. K.  
Locked Mode  
(Vandal Proof)  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
Troubling Shooting Guide to complete installation. Stopper will be  
in “Locked” mode and not be removable.  
Unlocked Mode:  
Look at the Plastic Loop at the bottom of the Stopper and notice  
that the Loop is on one side of the Stopper. Fig. H.  
Fig. H.  
LOGO  
To install the stopper in “Unlocked” mode, insert the Stopper into  
the Drain so that the Plastic Loop is facing toward the front of the  
Sink and the American Standard logo is facing rear. Rotate Stopper  
slightly if necessary so that the Stopper slides all the way down.  
Fig. H.  
180˚  
Re-install the Cam into the Drain, rotating the Cam if necessary  
to make sure it is fully inserted. Fig. J.  
LOOP TOWARD  
FRONT OF SINK  
Re-install the Cam Cap, making sure the guide teeth are facing  
outward. If the Cam Cap does not “snap” into place, then rotate  
the Cam to make sure it is fully inserted. Fig. K.  
DRAIN  
Unlocked Mode  
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in  
“Troublingshooting Guide” to complete installation. Stopper will be  
in “Unlocked” mode and removable.  
Fig. J.  
Fig. K.  
CAM  
INSTALL CAM  
INSTALL  
CAM CAP  
M968640 REV.1.1  
 
7
BERWICK/ BOULEVARD™  
SPREAD  
LAVATORY FITTING  
MODEL NUMBER  
M962817-YYY0A  
SPOUT KIT  
7431.801  
7430.801  
7430.821  
/
7431.821  
M962420-YYY0A  
POP-UP ROD  
M962837-YYY0A  
CROSS HANDLE  
ASSEMBLY  
M962832-YYY0A  
RIGHT LEVER  
HANDLE ASSEMBLY  
M962831-YYY0A  
LEFT LEVER  
HANDLE ASSEMBLY  
M962905-0070A  
SPOUT SET  
SCREW KIT  
M962818-0070A  
AERATOR KIT  
M962830-YYY0A  
ESCUTCHEON KIT  
A912831-0070A  
SPOUT O-RING  
918555-0070A  
HANDLE SCREW  
617852-0070A  
HANDLE ADAPTER  
M962492-0070A  
MOUNTING KIT  
M962544-YYY0A  
STOPPER  
ASSEMBLY  
994053-0070A  
M918462-0070A  
CABLE ADAPTER  
CARTRIDGE  
M952430-0070A  
CABLE ASSEMBLY  
M961634-0070A  
VALVE  
M962457-YYY0A  
FLANGE  
ASSEMBLY  
MOUNTING  
KIT  
M952425-YYY0A  
DRAIN ASSEMBLY  
M922872-0070A  
CAM SEAT INSERT  
M962552-0070A  
CAM ASSEMBLY  
024220-0070A  
COUPLING NUT  
M913207-0070A  
TAILPIECE INSERT  
Replace the "YYY" with  
appropriate finish code  
A923480-0070A  
SPACER  
CHROME  
SATIN NICKEL  
002  
295  
M919660-0020A  
A919661-0020A  
TAILPIECE  
6” TAILPIECE  
(NOT INCLUDED  
WITH FAUCET)  
M962458-0070A  
DRAIN MOUNTING KIT  
HOT LINE FOR HELP  
For toll-free information and answers to your questions, call:  
1 (800) 442-1902  
Weekdays 8:00 a.m. to 6:00 p.m. EST  
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)  
Weekdays 8:00 a.m. to 7:00 p.m. EST  
IN MEXICO 01-800-839-1200  
Product names listed herein are trademarks of American Standard Inc.  
© AS America,Inc. 2009  
M968640 REV.1.1  
 
8

ADC Network Card 600F User Manual
ADIC Network Card Scalar 1000 User Manual
Advantek Networks Network Card AWN PCI 54R User Manual
Agilent Technologies TV Converter Box 8590 User Manual
Aiwa Speaker System AWP ZX7 User Manual
Altinex Stereo Amplifier DA1222AT User Manual
Apple Network Card QuickTime Streaming Server Darwin Streaming Server User Manual
Avenview TV Converter Box C COMPVGA HDMI User Manual
Axis Communications Security Camera Q1614 E User Manual
Ayre Acoustics Stereo Amplifier K 5xe User Manual