Installation
Instructions
BERWICK™/ BOULEVARD™
SPREAD LAVATORY FAUCET
with Speed Connect™ Drain
7430.801
7430.821
7431.801
7431.821
7430.821
7431.821
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
7430.801
7431.801
Certified to comply with ANSI A112.18.1
Speed Connect Drain*
M968640 REV.1.1
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
*Your new American Standard faucet is designed to work only with the Speed Connect drain.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Tubing Cutter
Screwdriver
Channel Locks
Adjustable Wrench
Turn off hot and cold water
supplies before beginning.
CAUTION
INSTALL FAUCET
1
NOTE: READ STEP #16 BEFORE INSTALLING SPOUT TO CONVERT FROM SWIVEL TO FIXED SPOUT.
Seat SEAL (1) into under side of SPOUT BASE (2).
Feed FAUCET SUPPLIES (3), MOUNTING STUD (4) and DRAIN
CABLE ASSEMBLY (8) through the mounting hole of lavatory or
mounting surface. Figure A.
From below, slide DRAIN CABLE ASSEMBLY (8) and FAUCET SUPPLIES (3)
through opening in the SPACER (9) against underside of deck. Figure B.
Note: For thick deck installaitons the SPACER (9) is not required.
From below, push GASKET (7) and RETAINING WASHER (5) onto
MOUNTING STUD (4). Secure Faucet with MOUNTING NUT (6),
pulling faucet to front of sink, so SUPPLIES (3) rests against
mounting hole. Before final tightening, make sure collar on
MOUNTING NUT (6) is seated into RETAINING WASHER (5).
Figure B.
Figure A
Adjust Faucet so that it is centered. Tighten MOUNTING NUT (6)
to complete faucet mounting.
GROOVE
2
1
(FAUCET
BASE)
4
9
MOUNTING
SURFACE
3
5
7
5
Figure B
6
4
COLLAR ON
MOUNTING NUT
8
1
POP-UP DRAIN
5
6
Fig. A.
Fig. B.
Remove CLEAR PLASTIC COVER (1).
1
3
Remove CARDBOARD SPACER (2) from under
DRAIN POP-UP (3).
DRAIN
BODY
Tighten TAILPIECE (4) on DRAIN BODY before
installing DRAIN BODY. Fig. B.
2
4
REMOVE FLANGE
Fig. A.
Fig. B.
1
Thread FLANGE (1) counter-clockwise and remove
FLANGE (1) and FOAM GASKET (2) from drain
body. Fig. A.
Thread LOCKNUT (3) clock-wise to bottom of
drain body. Push GASKET (4) down against
LOCKNUT (3). Fig. B.
4
3
2
INSTALL DRAIN FROM
BELOW FIXTURE
TIGHTEN LOCKNUT
7
9
8
REAR OF SINK
Tighten LOCKNUT (1) firmly with Adjustable
Wrench or Channel Locks.
From under side of SINK
install DRAIN BODY (1) up
4
through drain outlet.
DRAIN
OUTLET
Note: No plumber’s putty
or caulk is required.
3
The CABLE ATTACHMENT
POINT (2) must face towards
the rear of the SINK.
1
1
2
Install FOAM GASKET (3) and
FLANGE (4) onto drain body
from above SINK and tighten
FLANGE (4) firmly.
FLANGE GASKET AND POP-UP KNOB
Fig. A.
DOWN
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET (3) is fully compressed
and not visible. Fig. A.
WHITE FOAM
GASKET
NOT VISIBLE
POP-UP KNOB (1) must be fully down. Fig. B.
DRAIN
FLANGE
1
M968640 REV.1.1
3
ATTACH CABLE CONNECTOR
10
Fig. A.
Fig. B.
Thread CABLE CONNECTOR (1) clockwise
onto DRAIN BODY CONNECTION (2) and
hand tighten. Fig. A.
1
Your new POP-UP DRAIN installation is
now complete. Fig. B.
Note: Tailpeice on pop-up drain is 1-1/4” O.D.
Fig. B.
2
1-1/4” O.D.
CHECK OPERATION OF POP-UP
11
Operate LIFT KNOB (1) to verify that STOPPER (2) opens and
closes.
Note: If STOPPER (2) does not open and close properly then refer
to the “troubleshooting section” of these instructions.
1
2
MAKE WATER SUPPLY AND WASTE CONNECTIONS
12
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3). Use
adjustable wrench to tighten connections.
COUPLING
NUT
Do not over tighten. Be careful not to kink copper supply when
bending. Use tubing cutter to cut to proper length.
1
2
3
FERRULE
M968640 REV.1.1
4
TEST INSTALLED FITTING
13
With HANDLES (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
6
1
Remove AERATOR (3). First loosen aerator set screw with
HEX WRENCH (6) supplied. Pull out AERATOR (3) with
AERATOR KEY (7).
AERATOR
SET
SCREW
Operate both HANDLES (1) to flush water
1
3
7
lines thoroughly.
Replace AERATOR (3) and tighten set screw.
5
CHECK DRAIN CONNECTIONS
14
Operate POP-UP KNOB (5) and fill Sink with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Sink. If STOPPER (4) does not seal properly, please
refer to “Troubleshooting Guide” in these instructions.
4
Release POP-UP KNOB (5) down and check all drain
connections and "P" trap for leaks.
if necessary.
Tighten
WASTE
OUTLET
2
COLD
“P” TRAP
2
HOT
SPOUT CAN BE FIXED OR SWIVEL.
CONVERT TO A FIXED SPOUT IF DESIRED.
SERVICE
15
16
To change from swivel to fixed spout, proceed as follows:
Remove PLUG BUTTON (1) from back of spout. VIEW “A”
Remove SET SCREW (2) using screwdriver.
Install FIXING SET SCREW (3) using Hex Wrench supplied.
Align SPOUT (4) and tighten SET SCREW (3) to secure SPOUT (4).
Replace PLUG BUTTON (1).
To change direction of handle
rotation, proceed as follows:
Turn valve to OFF position.
Thread counter-clock wise
HANDLE BASE (1) to remove
HANDLE ASSEMBLY (2) from
ESCUTCHEON BASE (3).
Use a flat blade screw driver
to remove SPRING CLIP (4).
Lift STOP WASHER (5), turn 90˚
and replace.
Replace SPRING CLIP (4).
Reinstall HANDLE ASSEMBLY (2).
2
1
1
3
VIEW "A"
4
If spout drips, operate handles
several times from OFF to ON
position. Do not force - handles
turn only 90˚.
2
90˚
5
3
VIEW "A"
4
1
VALVE
CARE INSTRUCTIONS:
17
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968640 REV.1.1
5
Speed Connect™ Drain
Troubleshooting Guide
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
• Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode.
CABLE ADJUSTMENT PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration. Fig. B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position. Fig. B, C.
Push DOWN on the Lift-Knob to make sure it is fully down. Fig. C.
Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the
Drain Body Connection (2) and hand-tighten. Fig. A.
Fig. A.
Fig. B. Fig. C.
DOWN
CAM
1
RE-ATTACH
CAM CAP
1
STOPPER
DISCONNECT
2
STOPPER REMOVAL PROCEDURE
Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration. Fig. B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. Fig. D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. Fig. E.
The Stopper can now be removed by lifting it out of the Drain. Fig. F.
Fig. F.
Fig. D.
Fig. E.
REMOVE
CAM
REMOVE
CAM CAP
M968640 REV.1.1
6
STOPPER INSTALLATION PROCEDURE
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. G.
Fig. G.
LOGO
To install the stopper in “Locked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the rear of the
Sink and the American Standard logo is facing front. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.Fig. G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
REAR OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
DRAIN
the Cam to make sure it is fully inserted. Fig. K.
Locked Mode
(Vandal Proof)
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in “Locked” mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper. Fig. H.
Fig. H.
LOGO
To install the stopper in “Unlocked” mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the front of the
Sink and the American Standard logo is facing rear. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig. H.
180˚
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted. Fig. J.
LOOP TOWARD
FRONT OF SINK
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted. Fig. K.
DRAIN
Unlocked Mode
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in “Unlocked” mode and removable.
Fig. J.
Fig. K.
CAM
INSTALL CAM
INSTALL
CAM CAP
M968640 REV.1.1
7
BERWICK™/ BOULEVARD™
SPREAD
LAVATORY FITTING
MODEL NUMBER
M962817-YYY0A
SPOUT KIT
7431.801
7430.801
7430.821
/
7431.821
M962420-YYY0A
POP-UP ROD
M962837-YYY0A
CROSS HANDLE
ASSEMBLY
M962832-YYY0A
RIGHT LEVER
HANDLE ASSEMBLY
M962831-YYY0A
LEFT LEVER
HANDLE ASSEMBLY
M962905-0070A
SPOUT SET
SCREW KIT
M962818-0070A
AERATOR KIT
M962830-YYY0A
ESCUTCHEON KIT
A912831-0070A
SPOUT O-RING
918555-0070A
HANDLE SCREW
617852-0070A
HANDLE ADAPTER
M962492-0070A
MOUNTING KIT
M962544-YYY0A
STOPPER
ASSEMBLY
994053-0070A
M918462-0070A
CABLE ADAPTER
CARTRIDGE
M952430-0070A
CABLE ASSEMBLY
M961634-0070A
VALVE
M962457-YYY0A
FLANGE
ASSEMBLY
MOUNTING
KIT
M952425-YYY0A
DRAIN ASSEMBLY
M922872-0070A
CAM SEAT INSERT
M962552-0070A
CAM ASSEMBLY
024220-0070A
COUPLING NUT
M913207-0070A
TAILPIECE INSERT
Replace the "YYY" with
appropriate finish code
A923480-0070A
SPACER
CHROME
SATIN NICKEL
002
295
M919660-0020A
A919661-0020A
TAILPIECE
6” TAILPIECE
(NOT INCLUDED
WITH FAUCET)
M962458-0070A
DRAIN MOUNTING KIT
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-1200
Product names listed herein are trademarks of American Standard Inc.
© AS America,Inc. 2009
M968640 REV.1.1
8
|