Installation
Instructions
2064.451
™
SERIN
WALL MOUNT FAUCET
IN-WALL LAVATORY FITTING
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
Certified to comply with ASME A112.18.1M
U.S. Patent No. 5,819,789
To ensure that your installation proceeds smoothly--
please read these instructions carefully before you begin.
M968852 Rev.1.3
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
ROUGHING-IN DIMENSIONS
3" MAX.
(76mm) MAX.
2" MIN.
(51mm)
8"
(203mm)
4"
(102mm)
CROSS
HANDLE
1"
(25mm)
FINISHED
WALL
2" D.
(52mm)
COLD
HOT
1/2" NPT INLETS
2" D.
(52mm)
2-1/8" D.
(54mm)
FINISHED
WALL
2" MAX. (51mm) MAX.
9-1/4"
(235mm)
1-1/4" O.D.
(32mm) O.D.
Required Tools
Adjustable Wrench
Channel Locks
Pipe Wrench
Plumbers' Putty or
Caulking
Teflon Tape
Flat Blade Screwdriver
Tubing Cutter
CROSS BRACE
Turn off hot and cold water
supplies before beginning.
INSTALL VALVE BODY
CAUTION
1
WOOD SCREWS
1
Determine where the finished wall location will be. This measurement
is very important! Note: The rough-in measurement from the finished
wall is; 2" minimum and 3" maximum. This is a 1" tolerance. See
rough-in illustration above.
WALL STUDS
Secure FAUCET BODY (1) to cross brace of wall structure
at required height using two wood screws.
Connect HOT water supply to left VALVE inlet and COLD water
supply to right VALVE inlet. Use pipe sealant or Teflon tape for
all threaded connections. For sweat connections, do not make
sweat connections directly to valve body. Damage to seals and
and valve cartridge may occur.
M
E
Turn valves to off position. Turn hot and cold supplies on and
check fitting connections for leaks .
16"
COLD
HOT
Complete wall construction.
SERVICE
5
3
To change direction of handle rotation,
proceed as follows:
4
Turn valve to OFF position.
Thread counter-clock wise HANDLE BASE (1) to remove
HANDLE ASSEMBLY (2) from ESCUTCHEON BASE (3).
Use a flat blade screw driver to remove SPRING CLIP (4).
Lift STOP WASHER (5), turn 90˚ and replace.
Replace SPRING CLIP (4).
1
TO REMOVE
HANDLE
90˚
Reinstall HANDLE ASSEMBLY (2).
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
5
2
TEST INSTALLED FAUCET
6
Turn HANDLES to "off" position.
Remove AERATOR (1) using TOOL (2) supplied.
Turn hot and cold water supplies on. Operate
both HANDLES to flush water lines thoroughly.
Check spout connections for leaks.
Check all drain connections for leaks.
Turn handles to OFF position. Replace AERATOR (1).
1
2
CARE INSTRUCTIONS:
7
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
M968852 Rev.1.3
™
SERIN
WALL MOUNT
LAVATORY FAUCET
MODEL NUMBER
2064.451
M962423-YYY0A
SPOUT ESCUTCHEON KIT
M962422-YYY0A
SPOUT ASSEMBLY
M962352-0070A
SPOUT MOUNTING KIT
994053-0070A
CARTRIDGE
617852-0070A
ADAPTER
M962757-0070A
AERATOR
918555-0070A
HANDLE SCREW
621423-0070A
VALVE HOUSING
M962424-YYY0A
HANDLE ESCUTCHEON KIT
M950245-YYY0A
HANDLE ASSEMBLY
Replace the "YYY" with
appropriate finish code
CHROME
SATIN NICKEL
002
295
015025-YYY0A
DRAIN COMPLETE
070532-0040A
TAILPIECE
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
Product names listed herein are trademarks of American Standard Inc.
© AS America, Inc. 2008
M968852 Rev.1.3
|