EIR508 Series-5107qsg
Quick Start Guide
4
3
DIP Switch Settings
LED Chart
Elinx Managed Ethernet Switch
EIR508 Series
LED
Status
Green
Off
Green
Off
Green
Off
Yellow
Off
Green
Off
Green
Blinking
Off
Yellow
Blinking
Off
Green
Yellow
Meaning
The Switch is powered on
The Switch is powered off
Power Source 1 is available
Power Source 1 is unavailable
Power Source 1 is available
Power Source 2 is unavailable
Power Source failure or Port Failure
Normal Operation
Ring Master (Master of a redundant ring)
The switch is not a Ring Master
The port is linked
The port is receiving or transmitting packets
No device attached
Power
Pos Status Description
OFF
Disable port 1 Alarm
Power 1
Power 2
Fault
1
2
3
4
5
Enable port 1 Alarm
(If port 1 link fails, the fault LED will light)
Disable port 2 Alarm
Enable port 2 Alarm
(If port 2 link fails, the fault LED will light)
Disable port 3 Alarm
Enable port 3 Alarm
(If port 3 link fails, the fault LED will light)
Disable port 4 Alarm
Enable port 4 Alarm
(If port 4 link fails, the fault LED will light)
Disable port 5 Alarm
Enable port 5 Alarm
(If port 5 link fails, the fault LED will light)
ON
OFF
ON
OFF
ON
R.M.
LNK/ACT
Ports 7 & 8
OFF
ON
Full Duplex Mode
Data Collision
Half Duplex Mode
OFF
ON
FDX/COL
Ports 7 & 8
10/100 Ports
OFF
Disable port 6 Alarm
6
7
8
9
Enable port 6 Alarm
(If port 6 link fails, the fault LED will light)
Disable port 7 Alarm
Enable port 7 Alarm.
ON
OFF
ON
1
2
5
(If port 7 link fails, the fault LED will light)
Items Included
Hardware Installation
OFF
ON
Disable port 8 Alarm
Enable port 8 Alarm
o
o
o
o
Ethernet Switch
(If port 8 link fails, the fault LED will light)
Disable the ring master function.
Enable the switch as the ring master
in the redundant ring group.
CD with Support Manual
This Quick Start Guide
Panel Mount Bracket
o
Record the switch’s MAC Address in the space
provided. The MAC Address is printed on the product
label. Provide the MAC Address to your Network
Administrator. The Network Administrator should
provide an IP Address, Subnet Mask, and Gateway.
Select a mounting location and install with the attached
DIN rail clip or included panel mount kit.
OFF
ON
o
o
Default Settings
Connect power to the switch
o
o
12 to 48 VDC
Redundant DC input is available with fault
contacts.
o
o
o
o
IP Address: 192.168.16.1
Subnet Mask: 255.255.255.0
Gateway: 192.168.16.254
User Name: root, Password: root
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland
+353 91 792444 Fax +353 91 792445
|