Model: RMR203HG
USER MANUAL
CONTENTS
Overview...........................................................................2
Front View...........................................................................2
Back View............................................................................2
Remote Sensor...................................................................3
Getting Started..................................................................3
Insert Batteries....................................................................3
RemoteSensor...................................................................3
Sensor Data Transmission.................................................4
Clock.................................................................................4
Clock Reception..................................................................4
Manually Set Clock............................................................5
Temperature And Humidity............................................5
Ice Warning.........................................................................5
Backlight..........................................................................5
Reset................................................................................5
Precautions......................................................................5
Specifications..................................................................6
About Oregon Scientific..................................................6
1
RMR203HG IM EN R5.indd
1
2007.8.9 5:27:36 PM
REMOTE SENSOR (FIG 3)
MEANING
LOCATION
Clock / alarm
Main unit batteries low
Sensor batteries low
2
3
Outdoor temperature
and humidity area
1
REMOTE SENSOR
4
5
The main unit can collect data from up to 3 sensors.
To set up the sensor:
1. Open the battery compartment (see FIG 3).
2. Select a channel then press RESET.
3. Close the battery door.
4. Place the sensor within 30 m (98 ft) of the main unit
using the table stand or wall mount.
TIP Ideal placements for the sensor would be in any
location on the exterior of the home at a height of not more
than 1.5 m (5 ft) and which can shield it from direct sunlight
or wet conditions for an accurate reading.
1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole
5. CHANNEL switch
GETTING STARTED
INSERT BATTERIES
1. Remove the battery compartment.
2. Insert the batteries, matching the polarities (see FIG
2).
3
RMR203HG IM EN R5.indd
3
2007.8.9 5:27:41 PM
ICON
DESCRIPTION
Main unit is searching for
sensor(s).
A channel has been found.
The sensor cannot be
found.
1.5 m (5 ft)
TIP The transmission range may vary depending on many
factors. You may need to experiment with various locations
to get the best results.
CLOCK
CLOCK RECEPTION
Use alkaline batteries for longer usage and
consumer grade lithium batteries in temperatures below
freezing.
This product is designed to synchronize its clock
automatically with a clock signal.
Slide EU / UK to select the signal received.
SENSOR DATA TRANSMISSION
To search for a sensor:
•
EU: DCF-77 signal: within 1500 km (932 miles) of
Frankfurt, Germany.
•
UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn,
England.
Press and hold
+ MODE simultaneously.
The sensor reception icon in the remote sensor area shows
the status:
To enable / disable signal reception:
Press and hold
reception.
to enable or
to disable signal
Reception takes 2-10 minutes. If the signal is weak,
it can take up to 24 hours to get a valid signal. If signal
4
RMR203HG IM EN R5.indd
4
2007.8.9 5:27:44 PM
reception is unsuccessful, place your unit next to a window,
press and hold to force another signal search.
Clock signal reception indicator:
To auto-scan between sensors:
Press and hold
+ MEM to display each sensor’s data for
3 seconds. To end press
.
To toggle between current, minimum and maximum
records for the selected sensor:
STRONG
SIGNAL
WEAK
SIGNAL
NO SIGNAL
Press MEM repeatedly.
To clear the records:
Press and hold MEM.
ICE WARNING
MANUALLY SET CLOCK
If the channel 1 sensor falls between 3°C to -2 °C (37°F to
28°F), LED indicator will flash, and will stop flashing once
the temperature is out of this range.
To set the clock manually, disable the signal reception first.
1. Press and hold MODE.
2. Press
or
to change the settings.
3. Press MODE to confirm.
BACKLIGHT
4. The settings order is: time zone, 12/24 hr format, hour,
minute, year, calendar mode (day – month / month–
day), month, day and language.
Press LIGHT to activate backlight for 5 seconds.
RESET
Time zone offset sets the clock +/- 23 hours from the
received clock signal time.
Press RESET to return to the default settings.
The language options are English (E), German (D),
French (F), Italian (I), and Spanish (S).
PRECAUTIONS
•
•
•
•
Do not subject the unit to excessive force, shock, dust,
temperature or humidity.
To select display mode:
Press MODE to choose between clock with seconds /
weekday / calendar.
Do not cover the ventilation holes with any items such
as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid over
it, dry it immediately with a soft, lint-free cloth.
TEMPERATURE AND HUMIDITY
To toggle temperature unit:
Press °C / °F.
Do not clean the unit with abrasive or corrosive
materials.
5
RMR203HG IM EN R5.indd
5
2007.8.9 5:27:46 PM
•
•
•
•
•
Do not tamper with the unit’s internal components. This
invalidates the warranty.
Weight
241 g (8.5 oz) without battery
-5°C to 50°C (23°F to 122°F)
0.1°C (0.2°F)
Only use fresh batteries. Do not mix new and old
batteries.
Temperature range
Resolution
Images shown in this manual may differ from the actual
display.
Signal frequency
Humidity range
Humidity resolution
Power
433 MHz
When disposing of this product, ensure it is collected
separately for special treatment.
25% - 95%
Placement of this product on certain types of wood
may result in damage to its finish for which Oregon
Scientific will not be responsible. Consult the furniture
manufacturer's care instructions for information.
1%
2 x UM-3 (AA) 1.5 V batteries
REMOTE UNIT (THGN132N)
•
•
The contents of this manual may not be reproduced
without the permission of the manufacturer.
L x W x H
50 x 22 x 96 mm
(1.97 x 0.87 x 3.78 in)
62 g (2.22 ounces)
Do not dispose old batteries as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
Weight
•
Please note that some units are equipped with
battery safety strip. Remove the strip from the battery
compartment before first use.
a
Transmission range
Temperature range
Humidity range
Power
30 m (98 ft) unobstructed
-20°C to 60°C (-4°F to 140°F)
25% - 95%
The technical specifications for this product and the
contents of the user manual are subject to change without
notice.
1 x UM-3 (AA) 1.5 V batteries
ABOUT OREGON SCIENTIFIC
about Oregon Scientific products.
SPECIFICATIONS
If you’re in the US and would like to contact our Customer
Care department directly, please visit:
www2.oregonscientific.com/service/support.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit:
TYPE
DESCRIPTION
MAIN UNIT
L x W x H
73 x 47 x 132.5 mm
(2.87 x 1.85 x 5.22 in)
6
RMR203HG IM EN R5.indd
6
2007.8.9 5:27:47 PM
www2.oregonscientific.com/about/international.asp.
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Temperature
and Humidity Station withAtomicTime (Model: RMR203HG)
is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. A copy of the
signed and dated Declaration of Conformity is available on
request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVED COMPLIED
All EU countries, Switzerland CH
and Norway
N
7
RMR203HG IM EN R5.indd
7
2007.8.9 5:27:47 PM
|