Aiphone Indoor Furnishings N 20AS User Manual

0108  
n
Add-on Selectors for the NEM Lamp Memory System  
N-20AS, 20-call  
N-40AS, 40-call  
- INSTRUCTIONS -  
The N-20AS and N-40AS add-on selectors are designed to function with the NEM Lamp Memory System, Type  
"C" or later. Multiple add-on selectors can be added to a master station along with a variety of sub stations to  
create a communication system tailored to a user's needs. All standard NEM system accessories can be used in  
conjunction with the add-on selectors. Each add-on selector requires a dedicated 24V DC power supply.  
1
2
NAMES & FUNCTIONS:  
1. OFF button  
2. Selector button  
3. OFF LED  
4. Directory card  
5. Station selector LED  
N-nAS TERMINAL DEFINITIONS:  
+
-
Positive 24V DC  
Negative  
1~40 Station number  
E
Common communication  
V1-V4 Connects to NB-U for  
A1-A4 Background Music  
3
4
5
Individual Components for System:  
NEM-n Master station (10, 20, 30, 40-call sizes)  
NEM-nA Master station with handset (10, 20, 30, 40-call sizes)  
NA-series Any sub station with NA, NB, or NE model number prefix  
PS-2420UL 24V DC, 2A Power Supply  
Other Accessory items listed in catalog or price list as compatible with the NEM series.  
SPECIFICATIONS:  
Power Source:  
Communication Output: 500mW at 20 ohms  
24V DC. Use PS-2420UL.  
Communication:  
All call output:  
Calling:  
Push-to-talk, release-to-listen (TALK button), or VOX handset at master (handset models only).  
Hands free at sub station.  
6W in a system of up to 20 sub stations  
12W in a system between 21 and 40 stations.  
Master to sub: By voice only after pretone.  
Sub to master: Call button on sub activates tone and LED, remaining activated until answered.  
2 conductors homerun to sub station, or loop multi-conductor cable with 1 common wire  
plus 1 individual wire per sub station on the wire run.  
Wiring:  
Shielded cable is recommended. Use Aiphone #822202 (22AWG) or #821802 (18AWG) 2 cond.  
Multiconductor: Aiphone #822210 (10 cond.), #822215 (15 cond.), #822220 (20 cond.)  
420' with 22AWG; 1,000' with 18AWG.  
Wiring Distance:  
Pg. 1  
 
TERMINAL LAYOUT:  
N-20AS  
Brass Jumper Brass Jumper  
N-nAS TERMINAL DEFINITIONS:  
+
-
Positive 24V DC  
Negative  
V1 A1 V2 A2  
+ -  
1~40 Station number  
E
Common communication  
E
E
E
8
E
7
E
6
E
5
E
4
E
3
E
2
E
1
V1-V4 Connects to NB-U for  
A1-A4 Background Music  
10  
9
N-40AS  
20 19 18 17 16 15 14 13 12 11  
10  
9
8
7
6
5
4
3
2
1
20 19 18 17 16 15 14 13 12 11  
Brass Jumper Brass Jumper Brass Jumper Brass Jumper  
30 29 28 27 26 25 24 23 22 21  
40 39 38 37 36 35 34 33 32 31  
+
-
V1 A1 V2 A2 V3 A3 V4 A4  
E
E
E
E
E
E
E
E
E
E
OPERATION:  
* POWER SWITCH ON MASTER MUST BE ON FOR SYSTEM TO BE OPERABLE.  
1. When a station calls in, press the selector button corresponding to the lit LED. Station will continue to ring and  
station LED will remain illuminated until the call is answered at the master or reset at the sub.  
2. To speak to the person at the remote station, press the TALK button on the master, and release TALK button  
to hear reply. If the master is equipped with a handset, communication can be with the handset or push-to-  
talk. Communication via the handset is VOX (voice actuated).  
3. When the conversation is completed, press the OFF button to the left of the station button that is selected.  
Hang up handset.  
CAUTION  
* Do not connect any AC wires to any terminal on any unit, as damage may occur. Connect only specified power source to + and - terminals.  
* Do not install more or different power sources than specified for the system.  
* Do not attempt to install or connect wires on the NEM system while the system's power supply is plugged in.  
* NEM masters and related equipment, unless specified as "weather resistant", are designed for indoor use only. Door stations (NE-DA, NE-JA,  
NE-SS, NE-SSR and NE-NVP) may be installed outdoors in a protected area. Do not expose any equipment directly to rain or extreme weather  
conditions.  
IMPORTANT  
* Any other manufacturer's products installed with the system (power supply, external device, etc.) are not covered under Aiphone's warranty.  
* Do not mount NEM equipment in the following places, as it may cause the system to malfunction:  
- High or extreme cold temperature areas: under direct sunlight, near equipment that varies in temperature, in front of air conditioner,  
inside a refrigerated area, etc.  
- Places subject to moisture or humidity extremes.  
- Places subject to environmental conditions, such as dust, oil, chemicals, salt, etc.  
* NEM units are electronic devices, which must not be subjected to water or any other liquid.  
* Severe weather conditions, such as lightning storms, may cause damage to NEM equipment. We recommend that power surge protection be  
installed to minimize potential component level damage.  
- Install the SA-1 surge arrestor to protect the power supply from a surge.  
- Additional SA-1 surge arrestors should be installed on all communication lines (one SA-1 for every two connected to master.).  
For additional information about this system,  
please refer to the standard NEM instructions.  
Aiphone Communication Systems  
1700 130th Ave. N.E.  
Bellevue, WA 98005  
(425) 455-0510  
Toll Free Technical Support:  
Pg. 3  
N-20,40AS Instr.  
0108JD  
1-800-692-0200  
FAX (425) 455-0071  
 

Abocom Network Router MC 56SVV User Manual
Accusplit Fitness Electronics 1691M17 User Manual
Acer Personal Computer Panel PC 1000 User Manual
Acer Projector P5271n User Manual
Aiwa Stereo Receiver AV D55 User Manual
Alliance Laundry Systems Washer HWTB21 User Manual
Allied Telesis Switch AT 8000S 16 User Manual
Allied Telesis Switch XEM 12S User Manual
Bacharach Carbon Monoxide Alarm Residential Combustion Analyzer User Manual
Eureka Tents Tent Spitfire User Manual